Reduction of helium loss from a superconducting accelerating cavity during initial cool-down and cryostat exchange by pre-cooling the re-condensing cryostat
https://aist.repo.nii.ac.jp/records/2001843
https://aist.repo.nii.ac.jp/records/20018433d554e2a-b381-463f-92be-6ffa665f562e
| Item type | Research Data (v9)(1) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PubDate | 2014-01-01 | |||||||||||||||
| Data name | ||||||||||||||||
| Title | Reduction of helium loss from a superconducting accelerating cavity during initial cool-down and cryostat exchange by pre-cooling the re-condensing cryostat | |||||||||||||||
| Language | en | |||||||||||||||
| Description of data | ||||||||||||||||
| Description Type | Abstract | |||||||||||||||
| Description | A Zero-Boil-Off (ZBO) cryostat is designed to realize a compact, stand-alone cryogenic system for the AIST superconducting accelerator (SCA). Under normal operation there is no evaporative helium loss from the cryomodule and therefore operating costs associated with the supply of liquid helium can be eliminated. The only significant loss of helium from the module occurs during the initial cavity cool-down procedure or when the re-condensing cryostat is replaced. It takes about 3 hours to cool down the cryostat head from room temperature (300 K) to 4 K. During this time around 100 L of liquid helium are lost to evaporation. By pre-cooling the cryostat inside a low heat load vacuum tube before transfer to the cryomodule, this evaporative loss could be essentially eliminated, significantly reducing the volume of liquid helium required for the initial cryomodule cool-down. The pre-cooling system also provides an efficient method to test the cryostat prior to use. | |||||||||||||||
| Language | en | |||||||||||||||
| Author (Creator) name |
ORourke Brian
× ORourke Brian
× 峰原 英介
× 林崎 規託
× 大島 永康
× 鈴木 良一
|
|||||||||||||||
| Access Rights | ||||||||||||||||
| Access Rights | open access | |||||||||||||||
| Access Rights URI | http://purl.org/coar/access_right/c_abf2 | |||||||||||||||
| APC | ||||||||||||||||
| APC | Not required | |||||||||||||||
| Rights Holder | ||||||||||||||||
| Right Holder Name | ORourke Brian | |||||||||||||||
| Language | en | |||||||||||||||
| Publisher | ||||||||||||||||
| Publisher | ELSEVIER SCIENCE BV | |||||||||||||||
| Language | en | |||||||||||||||
| Date | ||||||||||||||||
| Date | 2014-01-01 | |||||||||||||||
| Date Type | Issued | |||||||||||||||
| Language | ||||||||||||||||
| Language | eng | |||||||||||||||
| Resource Type | ||||||||||||||||
| Resource Type Identifier | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||
| Resource Type | journal article | |||||||||||||||
| Identifier | ||||||||||||||||
| Identifier | 10.1016/j.nima.2014.11.053 | |||||||||||||||
| Identifier Type | DOI | |||||||||||||||
| Relation | ||||||||||||||||
| Relation Type | isVersionOf | |||||||||||||||
| Identifier Type | URI | |||||||||||||||
| Related Identifier | http://www.sciencedirect.com/science/article/pii/S0168900214013412 | |||||||||||||||
| Language | ja | |||||||||||||||
| Related Title | 関連 URI | |||||||||||||||
| Source Title | ||||||||||||||||
| Source Title | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | |||||||||||||||
| Language | en | |||||||||||||||
| Volume Number | ||||||||||||||||
| Volume | 776 | |||||||||||||||
| Page Start | ||||||||||||||||
| Start Page | 83 | |||||||||||||||
| Page End | ||||||||||||||||
| End Page | 86 | |||||||||||||||